Double-Column DR Machine HXDCDR-100

$27,583.00

SKU: HXDCDR-100 Category:
Quotation

Double-Column DR Machine Feature

  1. Double column design with ground rail, large range of projection area adjustment space, easily meet the various shooting needs
  2. Intelligent operation, lets you experience the ease and fun of work; Automatic optimization of tube tracking software system, and organization of the balanced processing technology, bring you a brand new experience

1. Flat Panel Detector

  1. Type of the detector: TFT monolithic amorphous silicon
  2. Panel size of the detector: 430mm*430mm
  3. Efficient imaging size of the detector: 17*17 inch
  4. Acquisition pixel matrix of the detector: ≥3072×3072
  5. The pixel pitch of the detector: ≤146 um
  6. The spatial resolution of the detector: 3.7LP/MM
  7. Pixel grayscale: 16-bit
  8. Time of image acquisition and transmission: 3s

2. High frequency and high voltage generator

  1. Max. Output power: 50kw
  2. Input power supply: 380 VAC three-phase
  3. Output voltage: 40~150kV
  4. Tube current range: 10~800mA
  5. Exposure time range: 1ms-10000ms
  6. mAs range: 0.1mAs~1000mAs
  7. Support AEC、APR automatic exposure
  8. Diagnostic Self-test and display

3. X-ray bulb tube assembly

  1. Focus: 0.6mm/1.5mm
  2. Nominal electric power: 21kVA/52kVA
  3. Max. KV: 150kV
  4. Anode target angle: 12°

4. Bed for radiography

  1. The longitudinal movement range: ±130 mm
  2. The lateral movement range: is ±280 mm

5. Vertical chest X-ray stand

Vertical movement range: 1400±20 mm

6. Radiography stand

  1. Rotation range of the tube assembly: ≥±90°; Positioning for each 90°
  2. Longitudinal movement range: 1640±20 mm
  3. Vertical movement range: 1180±20 mm

7. AEC (optional)

  1. The detection number of the outliers: 3
  2. Tube voltage range: 40-150KV
  3. Light time range: 1ms-10s

8. The grid and the beam-limiting device

  1. The grid material: Aluminum-based grid
  2. Size: 18×18 inch (48×48cm)
  3. Grid ratio: 10:1
  4. Density: 215C
  5. Grid Focal length: 1000mm

9. Workstation functions for image acquisition, processing, and diagnosis

  1. The Chinese user interface, standard DICOM3.0 image
  2. Workstation functions for image acquisition: adjust or preset window width/ window level, local automatic window level, preset window width/ window level, positive and negative image flipping, image flipping, rotation, image magnification and roam, image interpolation edge enhancement, local magnification, restoration, image annotation, text annotation/number annotation, image marking, ruler line segment measurement, square and round measurement, arbitrary shape measurement, angle measurement, automatic electron sharing, image stitching, acquisition and display of exposure index
  3. Software package for the special image acquisition control and software package for special parts protocol processing
  4. Functions of patient management, image acquisition, image processing (image correction, image flipping, USM sharpening, image filtering), image observation (provide the tools for observation and measurement), image stitching
  5. Image printing, DICOM printing, paper printing, manual printing for the displayed images, a single button for marking and printing the images, optional for different printers, film format, and number of prints, print queue control, stop/start the preset
  6. User personalization: showing the format and layout, default setting, toolbar setting, and parts protocol enhancement filter
  7. Image display: display configuration 1920×1080, HD display

10. Workstation

  1. CPU: Intel i5,3GHz or above
  2. Host memory: ≥8GB DDR4
  3. Hard disk: 1T/7200rpm large capacity and high-speed hard disk
  4. Workstation monitor: 24” IPS LCD monitor
  5. Network card and network interface: 1000M network card, 1000M network interface, Jumbo Frames: 9K
  6. DICOM3.0 interface
  7. Windows 10 64-bit SP1 (Professional Edition or higher)
Shopping Cart